- Ultra Density 4U 60-bay 3.5" 6Gb/sec SAS 2.0 storage enclosure
- Operation with either single I/O controller or dual I/O controller for redundant failove
- Hot-pluggable I/O controller(s) and dual redundant high efficiency power/cooling (APC) modules
- Four SFF-8088 6Gb/sec SAS 2.0 host and expansion connections per SAS I/O Controller
- Up to 60 SAS/SATA HDDs or 120TB capacity (using 2.0TB SAS/SATA HDD)
- Modular design increases product configuration flexibilility
- SAS Point-to-point connectivity isolates drive failures, increasing reliability and fault tolerance, and improving performance
- SAS daisy-chain expansion up to four DNS-1660 JBODs via SFF-8088 SAS cables
- Multiple Drive partitioning/split-bus zoning modes
- Available Now
|
 |
|
|
|
Ultra-Dense, Cost-effective SAS/SATA JBOD Expansion
The DataON DNS-1660 Ultra-Dense 6 Gb/s SAS/SATA JBOD solution enables massive data capacity applications, at a price/performance point per Gigabyte (GB) that meets your fast-moving business requirements. Besides functioning as a standalone external direct attached storage (DAS) JBOD for standard serial attached SCSI (SAS) host connect, With up to 60 3.5” form factor SAS and/or SATA Hard Disk Drives (HDDs) per 4U enclosure, the industry-unique DNS-1660 is an ultra-dense, space and power savings solution.
The DataON DNS-1660 fits nicely into a standard 19” wide, 1m long, 42U rack that easily creates a 30TB/U (w/ 2TB SATA HDDs) data expansion building block that can be zoned to up to four different DAS Hosts. Additional DNS-1660 JBODs can be daisy chained to support deeper storage pools as supported by industry standard SAS HBAs and SAS RAID HBAs
|
Host/expansion Interfaces
- One or two SAS JBOD I/O controller modules per system, with each I/O module supporting four 6Gb/sec SAS SFF-8088 connections
- 6Gb/sec SAS SFF-8088 connections can be used for host connections or as a combination of host connection and expansion and support up to 2,400 MB/sec bandwidth
- Daisy chaining of enclosures for overall number of drives will most likely be limited by the specific qualified SAS HBA or SAS RAID HBA used in the configuration
Capacity
- Up to 60 SAS/SATA HDDs or 120TB capacity per 4U enclosure (using 2TB HDDs)
Firmware
- SCSI Enclosure Services (SES) 3.0 Revision 01 based firmware
I/O Controller Features
- Auto-negotiate data path speeds
- In-band management
- Redundant cable support
- Four 6Gb/s SAS host and expansion (SFF-8088) connections each one supporting up to 2,400 MB/sec bandwidth
I/O Controller Models
- DNS-1660S Model:
- Single 6Gb/sec SAS JBOD I/O controller module with support for storage expansion enclosures
- DNS-1660D Model:
- Dual redundant 6Gb/sec SAS JBOD I/O modules, each with support for storage expansion enclosures
Performance
- Up to 2,400 MB/s (sustained reads) using 6Gb/s disk drives/SFF-8088 host connections
- Up to 1,200 MB/s (sustained reads) using 3Gb/s disk drives/SFF-8088 host connections
Redundant Hot-Swappable Components
- Up to two 6Gb/sec SAS JBOD I/O controller modules
- Two advanced power and cooling modules (APC)
- Two independent AC power inlets
- Up to 60 drives
Safety Standards
- IEC/EN/UL/CSA 60950-1, 2nd Edition
|
|
4U Rackmount Enclosure
- Without Cable Management Arms:
- Dimensions: 6.90 in. H x 16.56 in. W x 35.1 in. D (175.3 mm H x 420.6 mm W x 891.5 mm D)
- With Cable Management Arms:
- Dimensions: 6.90 in. H x 16.56 in. W x 39.17 in. D (175.3 mm H x 420.6 mm W x 994.9 mm D)
- Weight for DNS-1660 without HDDs Shipping Pallet Pack: 150 lbs (58kg) max
- Weight for DNS-1660 w/ 60 HDDs Shipping Pallet Pack: 280 lbs (127 kg) max
- Weight for DNS-1660 without HDDs for Rack Installation: 105 lbs (48 kg) max
Failure Notifications
- SCSI Enclosure Services (SES-3) over in-band interface and via LEDs
Disk Drives
- 60 independent 600 MB/s point-to-point connections to each SAS or SATA disk drive with dual-port access and failover by each I/O controller to each drive (SATA drive requires optional 2:1 Active MUX)
- Form factor: 3.5” SAS and SATA drives
- Rotational speed: 7200 RPM, 10K RPM and 15K RPM
- Interface: 6Gb/3Gb SAS; 6Gb/3Gb SATA
Maximum External Cable Lengths (Customer Supplied)
- 6Gb/sec or 3Gb/sec SAS: up to 6m
AC Power
- Input voltage: Auto ranging, 90-264V AC
- Input frequency: 47-63Hz
- Power factor correction: Per EN61000-3-2
- Input current
- JS, JD Models: 14.5A RMS max @ 110 VAC
- Maximum system continuous DC output power rating
- Efficiency
- 20% load @ 230V ~ 88%
- 50% load @ 230V ~ 92%
- 20% load @ 115V ~ 87%
- 50% load @ 115V ~ 90%
Environmental Protection
|
|
Drive Partitioning/split-bus zoning
- Single 6Gb/sec SAS JBOD I/O controller module can be zoned as 1x60, 2x30 or 4x15 via F/W control
- Dual 6Gb/s SAS JBOD I/O controller modules can be zoned as 1x60, 2x30 or 4x15 via F/W control as redundant for the Single IOM configuration or an exclusive Split Bus mode can be set such that 30 HDDs are mutually exclusive to the first IOM and the other 30 HDDs are mutually exclusive to the second IOM
Operating Environment
- Temperature: 5° to 35°C
- Temperature gradient: 20°C per hour
- Relative humidity: 10 to 80 percent (non-condensing)
- Humidity gradient: 10% per hour
- Altitude: -200 to 10,000 ft.
- Shock: 5G at 11ms, 1/2 sine wave pulse
- Vibration: 0.15Grms
- Acoustics: TBD Bels at normal operation tested to ISO7779
Non-Operating Environment
- Transit Non-Operating
- Temperature: -40° to 60°C
- Relative humidity: 10% to 90% (non-condensing)
- Vibration: 0.75G
- Standard Non-Operating
- Temperature: -40° to 70°C
- Relative humidity: 5% to 95% (non-condensing)
- Altitude: -200 to 40,000 ft.
- Shock: 10G at 11ms, 1/2 sine wave pulse
- Vibration: 0.5G at 5Hz to 500Hz
Electromagnetic Emissions and Immunity Standards
- Compliant with EN55022 :2006 + A1 :2007
- Compliant with EN55024-IT product family standard for Immunity
- Meet the requirements of IECS-003
Quality Standards
- Manufactured under an ISO 9002 registered quality system
Monitoring and Reporting
- Monitoring for temperature, advanced power and cooling modules including blower speed control, disk drives and I/O module(s)
- In-band reporting of all serial number, part number and revisions of each FRU and chassis
|
|